Study of beam profile measurement at interaction point in international linear collider
Study of beam profile measurement at interaction point in international linear collider
复制标题
DOI:
10.1016/j.nima.2009.07.027
复制
发表时间:
2009-01
影响因子:
1.4
通讯作者:
Kazutoshi Ito;A. Miyamoto;T. Nagamine;T. Tauchi;H. Yamamoto;Y. Takubo;Yutaro Sato
中科院分区:
文献类型:
--
作者:
Kazutoshi Ito;A. Miyamoto;T. Nagamine;T. Tauchi;H. Yamamoto;Y. Takubo;Yutaro Sato
At the international linear collider, measurement of the beam profile at the interaction point is a key issue to achieve high luminosity. We report a simulation study on a new beam profile monitor, called the pair monitor, which uses the hit distribution of the electron–positron pairs generated at the interaction point. We obtained measurement accuracies of 5.1%, 10.0%, and 4.0% for the horizontal (σx), vertical (σy), and longitudinal beam sizes (σz), respectively, for 50 bunch crossings.