THERMO-LUMINESCENCE DOSIMETRY OF GAMMA-RAYS FROM THE ATOMIC-BOMB AT HIROSHIMA USING THE PREDOSE TECHNIQUE
THERMO-LUMINESCENCE DOSIMETRY OF GAMMA-RAYS FROM THE ATOMIC-BOMB AT HIROSHIMA USING THE PREDOSE TECHNIQUE
复制标题
DOI:
10.2307/3577198
复制
发表时间:
1988-02-01
影响因子:
3.4
通讯作者:
ISHII, H
中科院分区:
文献类型:
--
作者:
NAGATOMO, T;ICHIKAWA, Y;ISHII, H
Thermoluminescence dosimetry measurements of .gamma. rays produced by the atomic bomb in Hiroshima were made by the predose technique using eight ceramic samples collected from five buildings located at distances between 1271 and 2051 m from the hypocenter. The results of our measurements are compared to both the newer dose estimates (Dosimetry System 1986) and older dose estimates (Tentative 1965 Doses) for survivors of the Hiroshima atomic bomb. In comparison with the older estimates, our results are larger by a factor of 2.3 at 1271 m and 3.9 at 2051 m. Our results and the newer estimates for Hiroshima differ by a factor of only 1.14 .+-. 0.16 on the average.