Corrosion behavior of a steel bar embedded in a cement-based conductive composite
Corrosion behavior of a steel bar embedded in a cement-based conductive composite
复制标题
嵌入水泥基导电复合材料中的钢筋的腐蚀行为
DOI:
10.1016/j.conbuildmat.2016.12.087
复制
发表时间:
2017
影响因子:
7.4
通讯作者:
He Zheng
中科院分区:
文献类型:
--
作者:
Qiao Guofu;Guo Bingbing;Li Zuohua;Ou Jinping;He Zheng
Corrosion behavior of a steel bar embedded in a cement-based conductive composite was the object of study described in this paper. First, the conductivity percolation curve of a carbon-fiber- (CF-) reinforced cement-based composite was obtained. The dry-wet cycle method was then adopted to accelerate the corrosion of the steel bar embedded in the cement-based conductive composite. The corrosion behavior was analyzed using the linear polarization resistance (LPR) technique, the corrosion potential and the weight loss method. In addition, the effect of the CF added on the pore structure was discussed. Finally, it was found that the percolation threshold of CF in the composite is a critical value that determines the corrosion level of the steel bar. The addition of CF has no effect on the corrosion level of the steel bar at the early stage when the CF content is lower than the CF percolation threshold, while the corrosion level tends to increase when the CF content is higher than the CF percolation threshold.