Use of simultaneous IR temperature measurements and DPIV to investigate thermal plumes in a thick layer cooled from above
Use of simultaneous IR temperature measurements and DPIV to investigate thermal plumes in a thick layer cooled from above
复制标题
DOI:
10.1007/s003480050330
复制
发表时间:
1999-06
影响因子:
2.4
通讯作者:
R. Volino;Geoffrey B. Smith
中科院分区:
文献类型:
--
作者:
R. Volino;Geoffrey B. Smith
Simultaneous measurements of surface temperature and the underlying velocity field are presented for a thick horizontal layer evaporatively cooled from above. Previous studies have focused on either the temperature field at the cooled surface or, in a small number of cases, on point velocity measurements in the flow. The current investigation is, to the knowledge of the authors, the first to simultaneously and non-intrusively document both the surface temperature and underlying velocity field in this type of flow. An infrared (IR) sensing array was used to capture the instantaneous free surface temperature field while two-dimensional velocity measurements in planes either perpendicular or parallel to the free surface were acquired using digital particle image velocimetry (DPIV). Data from two cases are discussed.