Precision and reliability for measurement of change in MRI lesion volume in multiple sclerosis: a comparison of two computer assisted techniques
Precision and reliability for measurement of change in MRI lesion volume in multiple sclerosis: a comparison of two computer assisted techniques
复制标题
DOI:
10.1136/jnnp.65.1.42
复制
发表时间:
1998-07-01
影响因子:
11
通讯作者:
Miller, DH
中科院分区:
文献类型:
--
作者:
Molyneux, PD;Tofts, PS;Miller, DH
Objective-The serial quantification of MRI lesion load in multiple sclerosis provides an effective tool for monitoring disease progression and this has led to its increasing use as an outcome measure in treatment trials. Segmentation techniques must display a high degree of precision and reliability if they are to be responsive to small changes over time. This study has evaluated the performance of two such techniques, the manual outlining and contour methods, in serial lesion load quantification.Methods-Sixteen patients with clinically definite multiple sclerosis were scanned at baseline and after two years. Scan analysis was performed twice, independently by three observers using each technique.Results-For the absolute lesion volumes the median intrarater coefficient of variation (CV) was 3.2% for the contour technique and 7.6% for the manual outlining method (p