Comparison of quantitative wall-motion analysis and strain for detection of coronary stenosis with three-dimensional dobutamine stress echocardiography.
Comparison of quantitative wall-motion analysis and strain for detection of coronary stenosis with three-dimensional dobutamine stress echocardiography.
复制标题
DOI:
10.1111/echo.12636
复制
发表时间:
2015-02
期刊:
影响因子:
--
通讯作者:
Holmes JW
中科院分区:
文献类型:
--
作者:
Parker KM;Clark AP;Goodman NC;Glover DK;Holmes JW
Quantitative analysis of wall motion from three-dimensional (3D) dobutamine stress echocardiography (DSE) could provide additional diagnostic information not available from qualitative analysis. In this study we compare the effectiveness of 3D fractional shortening (3DFS), a measure of wall motion computed from 3D echocardiography (3DE), to strain and strain rate measured with sonomicrometry for detecting critical stenoses during DSE. Eleven open-chest dogs underwent DSE both with and without a critical stenosis. 3DFS was measured from 3DE images acquired at peak stress. 3DFS was normalized by subtracting average 3DFS during control peak stress (Δ3DFS). Strains in the perfusion defect (PD) were measured from sonomicrometry, and PD size and location were measured with microspheres. A Δ3DFS abnormality indicated the presence of a critical stenosis with high sensitivity and specificity (88% and 100%, respectively), and Δ3DFS abnormality size correlated with PD size (R2=0.54). The sensitivity and specificity for Δ3DFS was similar to that for area strain (88%, 100%) and circumferential strain and strain rate (88%, 92% and 88%, 86%, respectively), while longitudinal strain and strain rate were less specific. Δ3DFS correlated significantly with both coronary flow reserve (R2=0.71) and PD size (R2=0.97), while area strain correlated with PD size only (R2=0.67), and other measures were not significantly correlated with flow reserve or PD size. Quantitative wall motion analysis using Δ3DFS is effective for detecting critical stenoses during DSE, performing similarly to 3D strain, and provides potentially useful information on the size and location of a perfusion defect.
登录
查看更多内容
影响因子:
3.3
作者:
Holmes, JW
通讯作者:
Holmes, JW
DOI:
10.1016/j.echo.2011.01.014
发表时间:
2011-03-01
影响因子:
6.5
作者:
Kleijn, Sebastiaan A.;Aly, Mohamed F. A.;Kamp, Otto
通讯作者:
Kamp, Otto
影响因子:
--
作者:
Amundsen, Brage H.;Crosby, Jonas;Stoylen, Asbjorn
通讯作者:
Stoylen, Asbjorn
影响因子:
37.8
作者:
Leong-Poi, H;Rim, SJ;Kaul, S
通讯作者:
Kaul, S
影响因子:
37.8
作者:
LIMA, JAC;BECKER, LC;WEISS, JL
通讯作者:
WEISS, JL