Postfiring stress‐strain hysteresis of concrete subjected to various heating and cooling regimes
Postfiring stress‐strain hysteresis of concrete subjected to various heating and cooling regimes
复制标题
DOI:
10.1002/fam.785
复制
发表时间:
2002-05
影响因子:
1.9
通讯作者:
A. Nassif
中科院分区:
文献类型:
--
作者:
A. Nassif
This paper reports an experimental investigation involving 90 siliceous aggregate concrete cores (75 mm dia. 175 mm long), which were subjected to 18 different heating and cooling regimes in the temperature range (217°C–470°C). The cores were heated to the point when the centre of the core reached the same temperature as the outer surface, the point of uniformity. Subsequently, the cores were either taken out of the furnace to cool or soaked at the test temperature for 2 h. Cooling was either by spraying the heated core with water for 5 min or by air‐cooling in a controlled environment of 20°C and 65% RH. The extent of damage and internal fracture were assessed using the stiffness damage test (SDT) and the ultrasonic pulse velocity (UPV) as well as petrography methods.