Analysis of composite floor cellular steel beams in fire
Analysis of composite floor cellular steel beams in fire
复制标题
复合楼板蜂窝钢梁火灾分析
DOI:
10.1260/2040-2317.1.3.161
复制
发表时间:
2010
影响因子:
1
通讯作者:
Sengkwan Choi
中科院分区:
文献类型:
--
作者:
A. Nadjai;N. Goodfellow;K. Tee;F. Ali;Sengkwan Choi
The growing popularity of the use of cellular steel beams in composite floors comes at the same time as an increasing attention to the fire safety engineering design. The recommendation for their design in fire limit states remains very primitive and this is due to the lack of general research in this area. Four composite cellular steel beams were tested at the University of Ulster with two models of different steel geometries and loading conditions under monotonic loading and at elevated temperatures. This paper presents a finite element model and simple hand calculation methods to calculate the shear buckling at the web post, the bending resistance in fire, deflection and temperature distribution in the cross section of composite cellular beams.