Robust parameter estimation in a model for glucose kinetics in type 1 diabetes subjects.

Robust parameter estimation in a model for glucose kinetics in type 1 diabetes subjects.
复制标题

1 型糖尿病受试者葡萄糖动力学模型中的稳健参数估计。

DOI:
10.1109/iembs.2006.260045
复制
发表时间:
2006
期刊:
Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
影响因子:
--
通讯作者:
Doyle3rd,FrancisJ
Doyle3rd,FrancisJ
中科院分区:
--
文献类型:
--
作者:
Palerm,CesarC;Rodríguez-Fernández,María;Bevier,WendyC;Zisser,Howard;Banga,JulioR;Jovanovic,Lois;Doyle3rd,FrancisJ

文献摘要

相似文献

There is a significant push to develop closed-loop control systems to deliver insulin for type 1 diabetic subjects. As part of this process, mathematical models are required to test and validate the proposed algorithms. There are several published physiology-based models of glucose and insulin dynamics in the literature, however, all of them were derived using data from subjects without diabetes. For this particular study we have selected one of the recently published models, by Hovorka et al. [1], replacing the subcutaneous insulin infusion model with the one described by Wilinska et al. [2]. Five subjects with type 1 diabetes underwent a hyperinsulinemic-euglycemic clamp with a meal challenge and corresponding subcutaneous insulin bolus. The data collected were used to fit the model parameters using global optimization methods. Our results show that the model is capable of describing the observed dynamics for type 1 subjects under the experimental conditions, and as such can be used to simulate subject behavior under the experimental conditions.