Secondary ion emission from solutions: time dependence and surface phenomena.
Secondary ion emission from solutions: time dependence and surface phenomena.
复制标题
溶液中的二次离子发射:时间依赖性和表面现象。
DOI:
10.1021/ac00047a030
复制
发表时间:
1992
影响因子:
7.4
通讯作者:
Todd,PJ
中科院分区:
文献类型:
--
作者:
Kriger,MS;Cook,KD;Short,RT;Todd,PJ
N (CH3) 3Br, TTAB) and tetraethylammonium Iodide (TEAI) was Investigated. FAB spectra of the TTAB solution displayed a continuous decrease In TTA+ with time. Spectra obtained from the TEAI solution were initially invariant for several minutes and then displayed a gradual Increase In the relative abundance of TEA+ to a maximum, followed by a precipitous drop In Ion Intensity. Secondary Ion images of droplets of TTAB solution showed that emission of both TTA+ and glycerol secondary Ions was homogeneous across the sample. Secondary Ion Images of droplets of TEAI solution showed heterogeneous and segregated emission of both TEA+ and protonated glycerol. Results from the FAB spectra and the secondary km Images were correlated and rationalized on the basis of surface tension-induced mass transport and matrix evaporation.