Effect of Power and Frequency on Bubble-Size Distributions in Acoustic Cavitation
Effect of Power and Frequency on Bubble-Size Distributions in Acoustic Cavitation
复制标题
DOI:
10.1103/physrevlett.102.084302
复制
发表时间:
2009-02-27
影响因子:
8.6
通讯作者:
Ashokkumar, Muthupandian
中科院分区:
文献类型:
--
作者:
Brotchie, Adam;Grieser, Franz;Ashokkumar, Muthupandian
Acoustic bubble-size distributions have been determined using a pulsed ultrasound method at different ultrasound powers and frequencies. It was observed that the mean bubble size increased with increasing acoustic power and decreased with increasing ultrasound frequency. It was also recognized that the mean size of bubbles emitting sonoluminescence was greater than those producing sonochemiluminescence indicating that the two processes take place in different populations of cavitation bubbles in the system.