Evaluation of indium-111 chloride as a radiopharmaceutical for joint imaging in a rabbit model of arthritis.
Evaluation of indium-111 chloride as a radiopharmaceutical for joint imaging in a rabbit model of arthritis.
复制标题
氯化铟 111 作为放射性药物用于兔关节炎模型关节成像的评价。
DOI:
10.1097/00004424-198709000-00007
复制
发表时间:
1987
影响因子:
6.7
通讯作者:
Sledge,C
中科院分区:
文献类型:
--
作者:
Zalutsky,MR;deSousa,M;Venkatesan,P;Shortkroff,S;Zuckerman,J;Sledge,C
The potential use of 111 In-chloride as a radiopharmaceutical for quantitating the extent of synovitis was investigated in a rabbit model of antigen-induced arthritis. Rabbits with monoarticular disease were injected with 111 In-chloride and imaged at 30 minutes and 24, 48, 72, and 96 hours. In control knee joints, the ratio of activity in the knee to a soft-tissue region in the thigh remained constant (1.5–1.85: 1); in arthritic knees, the 111 In uptake ratio increased from 2: 1 to 3.2, 3.5, 3.9, and 4.6: 1 at the later time points. The difference between the knee-to-soft-tissue ratios observed in the control and involved joints was significant (P<. 01, 48–96 hr). Tissue distribution measurements demonstrated that the synovium and intra-articular structures covered by synovium in arthritic joints had the highest concentration of 111 In. In control joints, these tissues were found to take up tenfold less activity. Good correlation was observed between the 111 In knee-to-soft-tissue ratios calculated from the images and histologic assessment of the severity of synovitis.