Determination of organophosphorus pesticides in biological samples of acute poisoning by HPLC with diode-array detector
Determination of organophosphorus pesticides in biological samples of acute poisoning by HPLC with diode-array detector
复制标题
DOI:
10.1248/cpb.45.737
复制
发表时间:
1997-04-01
影响因子:
1.7
通讯作者:
Kamiya, A
中科院分区:
文献类型:
--
作者:
Cho, Y;Matsuoka, N;Kamiya, A
We have developed a simple and rapid method for measuring 11 organophosphorus pesticides (dichlorvos, methidathion, salithion, malathion, fenitrothion, fenthion, parathion, diazinon, ethylthiometon, O-ethyl O-(4-nitrophenyl)phenylphosphonothioate (EPN) and chlorpyrifos) and one metabolite (3-methyl-3-nitrophenol) of fenitrothion in serum and urine of acute poisoning patients by HPLC with a diode-array detector. An aliquot of the biological sample after deproteinization by acetonitrile was injected into a C-18 column using acetonitrile-water as a mobile phase. The detection limits in serum and urine ranged from 0.05 to 6.8 mu g/ml at a wavelength of 230 nn. This method was successfully applied to two actual cases of acute poisoning.