Image reconstruction for the circle and line trajectory
Image reconstruction for the circle and line trajectory
复制标题
DOI:
10.1088/0031-9155/49/22/003
复制
发表时间:
2004-11-21
影响因子:
3.5
通讯作者:
Katsevich, A
中科院分区:
文献类型:
--
作者:
Katsevich, A
We propose an exact shift-invariant filtered backprojection algorithm for inversion of the cone beam data in the case when the source trajectory consists of an incomplete circle and a line segment. The algorithm allows for axial truncation of the cone beam data. The length of the line scan is determined only by the region of interest and is independent of the size of the entire object. The algorithm is quite flexible and can also be used for more general trajectories consisting of several (complete or incomplete) circles and line segments. Results of numerical experiments demonstrate good image quality.