Dzyubachyk, Oleh;Staring, Marius;van der Geest, Rob J.
PurposeTo develop and validate a method for performing inter-station intensity standardization in multispectral whole-body MR data.MethodsDifferent approaches for mapping the intensity of each acquired image stack into the reference intensity space were developed and validated. The registration strategies included: direct registration to the reference station (Strategy 1), progressive registration to the neighboring stations without (Strategy 2), and with (Strategy 3) using information from the overlap regions of the neighboring stations. For Strategy 3, two regularized modifications were proposed and validated. All methods were tested on two multispectral whole-body MR data sets: a multiple myeloma patients data set (48 subjects) and a whole-body MR angiography data set (33 subjects).ResultsFor both data sets, all strategies showed significant improvement of intensity homogeneity with respect to vast majority of the validation measures (P