Test-beam results of a silicon pixel detector with Time-over-Threshold read-out having ultra-precise time resolution

Test-beam results of a silicon pixel detector with Time-over-Threshold read-out having ultra-precise time resolution
复制标题

具有超精确时间分辨率的超阈值读出的硅像素探测器的测试光束结果

DOI:
10.1088/1748-0221/10/12/p12016
复制
发表时间:
2015
影响因子:
1.3
通讯作者:
B. Velghe
B. Velghe
中科院分区:
工程技术4区
文献类型:
--
作者:
G. Rinella;E. Gil;M. Fiorini;J. Kapłon;A. Kluge;F. Marchetto;M. Albarran;M. Morel;M. Noy;L. Perktold;S. Tiuraniem;B. Velghe

文献摘要

被引文献

相似文献

为NA 62实验中的束流跟踪而研制的时间标记混合硅像素探测器已在CERN的专用测试束中用10 GeV/c强子进行了测试。测量包括时间分辨率,检测效率和像素之间的电荷共享,以及由于偏置电压变化的影响。在200 μm厚的硅传感器上,采用像素级双稳放大器和基于列末DLL的时间-数字转换器,测量出小于150 ps的时间分辨率。
A time-tagging hybrid silicon pixel detector developed for beam tracking in the NA62 experiment has been tested in a dedicated test-beam at CERN with 10 GeV/c hadrons. Measurements include time resolution, detection efficiency and charge sharing between pixels, as well as effects due to bias voltage variations. A time resolution of less than 150 ps has been measured with a 200 μm thick silicon sensor, using an on-pixel amplifier-discriminator and an end-of-column DLL-based time-to-digital converter.