Load Voltage Regulation Method for an Isolated AC-DC Converter with Power Decoupling Operation
Load Voltage Regulation Method for an Isolated AC-DC Converter with Power Decoupling Operation
复制标题
DOI:
10.23919/ipec.2018.8506667
复制
发表时间:
2018-05
期刊:
影响因子:
--
通讯作者:
Shohei Komeda;H. Fujita
中科院分区:
文献类型:
--
作者:
Shohei Komeda;H. Fujita
This paper propose a new load voltage regulation method for an isolated single-phase ac-to-dc converter with power decoupling operation. The power decoupling operation has originally been proposed to achieve a unity displacement power factor in the line current. However, the unity displacement power factor operation can regulate the load voltage in a limited operating power range, and the load voltage decreases especially under a light load condition. The proposed control method does not compensate the leading current due to filter capacitors and make it possible to regulate the load voltage at a constant level in a wider power range. As a result, the proposed control method realizes an effective load voltage regulation with a higher power conversion efficiency by a 100-V, 300-W experimental setup.