Impurity intrusion in radio-frequency micro-plasma jets operated in ambient air
Impurity intrusion in radio-frequency micro-plasma jets operated in ambient air
复制标题
DOI:
10.1088/0022-3727/44/32/325201
复制
发表时间:
2011-05
期刊:
影响因子:
--
通讯作者:
B. Niermann;A. Kanitz;M. Böke;J. Winter
中科院分区:
文献类型:
--
作者:
B. Niermann;A. Kanitz;M. Böke;J. Winter
Space and time resolved concentrations of helium He (3S1) metastable atoms in an atmospheric pressure radio-frequency micro-plasma jet were measured using tunable diode laser absorption spectroscopy. Spatial profiles and lifetime measurements show significant influences of air entering the discharge from the front nozzle and of impurities originating from the gas supply system. Quenching of metastables was used to deduce quantitative concentrations of intruding impurities. The impurity profile along the jet axis was determined from optical emission spectroscopy as well as their dependence on the feed gas flow through the jet.