文献摘要

被引文献

相似文献

目的:本研究旨在探讨婴幼儿有意义听觉整合量表(IT-MAIS)、有意义听觉整合量表(迈斯)和有意义言语运用量表(MUSS)的信度和效度。对300例人工耳蜗植入儿童进行了调查。为了评估问卷的重测信度,随机抽取了30名儿童,每隔两周进行一次测试,结果表明,测试和重测之间没有显著性变化。结果:信度检验:三个量表的重测信度均较好。所有领域的相关系数均大于0.750(P < 0.01)。三个量表及其三个领域的Cronbach’s a均大于0.700。三个量表的评价者之间的可靠性被认为是令人满意的。所有领域的相关系数均大于0.750(P < 0.01)。有效性测试:专家评审内容效度评价结果表明,问卷具有较好的内容效度,三个量表总分与其三个领域的相关系数在0.699-0.978之间(P < 0.01)。三个子领域之间存在相关性,但相关强度相对较低。结论:IT-迈斯、迈斯、MUSS量表具有较好的信度和效度,可用于人工耳蜗植入儿童的听力言语评价。(C)2017爱思唯尔B. V.保留所有权利。
Objective: The aim of this study was to investigate the reliability and validity of the Infant-toddler Meaningful Auditory Integration Scale (IT-MAIS), Meaningful Auditory Integration Scale (MAIS), and Meaningful Use of Speech Scale (MUSS).Methods: IT-MAIS, MAIS and MUSS were divided into 3 sub dimensions. 300 children with cochlear implants (CI) were included in the investigation. To assess test-retest reliability of these questionnaires, 30 children were selected randomly to be evaluated at a two-week interval indicated that there were no significant changes between test and retest. Furthermore random test analysis by different evaluators was also administered to 30 users.Results: Reliability test: Test-retest reliability of the three scales was proved to be satisfactory. All domains had correlation coefficients that exceeded 0.750(P < 0.01). The Cronbach's a of the three scales and their three domains were greater than 0.700. Reliability between evaluators of the three scales were considered to be satisfactory. All domains had correlation coefficients that exceeded 0.750(P < 0.01). Validity test: The evaluation of content validity by expert review showed the questionnaire had good content validity; The correlation coefficients between the overall scores of the three scales and their three domains were 0.699-0.978(P < 0.01). There were correlations among the three sub-domains but the strength of the correlations was relatively low. There was certain construct validity.Conclusions: IT-MAIS, MAIS, MUSS scales have good reliability and validity, and can be used to measure the outcome for children with cochlear implants hearing and speech evaluation. (C) 2017 Elsevier B.V. All rights reserved.