Comparative performance of conventional OPC concrete and HPC designed by densified mixture design algorithm
Comparative performance of conventional OPC concrete and HPC designed by densified mixture design algorithm
复制标题
DOI:
10.1088/1757-899x/272/1/012035
复制
发表时间:
2017-12
期刊:
影响因子:
--
通讯作者:
Trong‐Phuoc Huynh;C. Hwang;Shu Yang
中科院分区:
文献类型:
--
作者:
Trong‐Phuoc Huynh;C. Hwang;Shu Yang
This experimental study evaluated the performance of normal ordinary Portland cement (OPC) concrete and high-performance concrete (HPC) that were designed by the conventional method (ACI) and densified mixture design algorithm (DMDA) method, respectively. Engineering properties and durability performance of both the OPC and HPC samples were studied using the tests of workability, compressive strength, water absorption, ultrasonic pulse velocity, and electrical surface resistivity. Test results show that the HPC performed good fresh property and further showed better performance in terms of strength and durability as compared to the OPC.