Influence of device non-uniformities on the accuracy of Coulomb blockade thermometry

Influence of device non-uniformities on the accuracy of Coulomb blockade thermometry
复制标题

装置非均匀性对库仑封锁测温精度的影响

DOI:
--
复制
发表时间:
2021
期刊:
影响因子:
2.4
通讯作者:
B. Karimi
B. Karimi
中科院分区:
工程技术3区
文献类型:
--
作者:
J. Pekola;Eemil Praks;N. Yurttagül;B. Karimi

文献摘要

参考文献

被引文献

相似文献

研究了隧道结阵列中不可避免的非均匀引起的库仑阻塞温度计(CBT)的温度不确定度。这些修正与线性工作区域内的结电阻变化成正比,并且这一结果在最初研究的高温范围之外也大致适用。我们给出了分析和数值结果,并简要讨论了它们对基于最先进的传感器制造的可实现的一致性的影响。
We investigate temperature uncertainty of Coulomb blockade thermometer (CBT) arising from inevitable non-uniformities in tunnel junction arrays. The corrections are proportional to the junction resistance variance in the linear operation regime and this result holds approximately also beyond this originally studied high temperature range. We present both analytical and numerical results, and discuss briefly their implications on achievable uniformity based on state-of-the-art fabrication of sensors.