Cancellation of Superficial Blood Flow in Brain Function Measurements Using Near-Infrared Spectroscopy
Cancellation of Superficial Blood Flow in Brain Function Measurements Using Near-Infrared Spectroscopy
复制标题
使用近红外光谱法测量脑功能时浅表血流的消除
DOI:
10.1109/embc.2019.8857057
复制
发表时间:
2019
期刊:
影响因子:
--
通讯作者:
Sato Daisuke
中科院分区:
文献类型:
--
作者:
Fukuda Keiko;Motoyoshi Daisuke;Sato Daisuke
In brain function measurement by near-infrared spectroscopy, reduction of signal fluctuation caused by the superficial blood flow is necessary. We proposed an equilateral-triangle-type sensor arrangement for cancelling superficial blood flow using short-distance detectors placed at the center of the triangle. We applied the independent components analysis (ICA) for this equilateral triangle configuration to improve the correction effect. We measured the change in blood volume caused by the motion artifacts according to the posture change and analyzed the correction effect of the ICA. It is shown that the ICA is more effective than simple subtraction and has small dependence on the measurement conditions and is applicable to this equilateral triangle configuration.