Passive ventricular constraint to improve left ventricular function and mechanics in an ovine model of heart failure secondary to acute myocardial infarction.
Passive ventricular constraint to improve left ventricular function and mechanics in an ovine model of heart failure secondary to acute myocardial infarction.
复制标题
被动心室约束可改善急性心肌梗死继发心力衰竭羊模型的左心室功能和力学。
DOI:
10.1016/s0022-5223(03)00739-6
复制
发表时间:
2003
期刊:
影响因子:
--
通讯作者:
M. Acker
中科院分区:
文献类型:
--
作者:
J. Pilla;A. S. Blom;D. Brockman;V. Ferrari;Q. Yuan;M. Acker
OBJECTIVEThis study investigated the effects on global cardiac function and myocardial energetics of limiting progressive dilatation after infarction by means of a woven polyester jacket cardiac support device. We hypothesized that placement of the cardiac support device results in a decrease in myocardial wall stress and improvement in cardiac function and myocardial energetics.METHODSTo investigate the effect of passive constraint on left ventricular function and mechanics, a total of 10 sheep were studied with pressure-volume analysis and magnetic resonance imaging. A baseline study was followed by the creation of an anterior infarct. After 1 week, the animals underwent a second study. The cardiac support device was then placed over the epicardium in 5 sheep; the remaining animals served as controls. A terminal study was performed at 2 months after the infarct.RESULTSThe cardiac support device group at the terminal study exhibited a decrease in end-diastolic volume (control 110.3 ± 19.8 mL vs cardiac support device 67.6 ± 4.7 mL, P = .006) and an improved ejection fraction (control 15.5% ± 5.7% vs cardiac support device 29.46% ± 4.42%, P = .008) relative to the control group. Myocardial energetics were also enhanced in the cardiac support device group, as evidenced by the significant improvements in potential energy (control 2015 ± 503 mL · mm Hg/beat vs cardiac support device 885 ± 220 mL · mm Hg/beat, P = .006), efficiency (control 39.4% ± 13.6% vs cardiac support device 59.8% ± 8.5%, P = .044), and oxygen consumption (control 0.072 ± 0.013 mL O2/beat vs cardiac support device 0.052 ± 0.007 mL O2/beat, P = .034).CONCLUSIONPassive constraint with the cardiac support device after infarct prevents further remodeling and may stimulate reverse remodeling in heart failure secondary to acute myocardial infarction. These results suggest that in human beings placement of the cardiac support device after a large anterior myocardial infarction may be effective in halting the remodeling process that often leads to end-stage heart failure. If proved effective, placement of a cardiac support device after large heart attacks has the potential to decrease the incidence of heart failure that results after large myocardial infarctions.
登录
查看更多内容
影响因子:
37.8
作者:
R. Edwards;M. Marber
通讯作者:
R. Edwards;M. Marber
影响因子:
37.8
作者:
GLOWER, DD;SPRATT, JA;RANKIN, JS
通讯作者:
RANKIN, JS
影响因子:
37.8
作者:
KASS, DA;YAMAZAKI, T;SAGAWA, K
通讯作者:
SAGAWA, K
影响因子:
158.5
作者:
PFEFFER, MA;LAMAS, GA;BRAUNWALD, E
通讯作者:
BRAUNWALD, E