Use of ultrasound in assessment of necrotic tissue in pressure ulcers with adjacent undermining.
Use of ultrasound in assessment of necrotic tissue in pressure ulcers with adjacent undermining.
复制标题
使用超声波评估邻近破坏的压疮中的坏死组织。
DOI:
10.12968/jowc.2011.20.11.503
复制
发表时间:
2011
影响因子:
1.9
通讯作者:
K. Tabata
中科院分区:
文献类型:
--
作者:
M. Ueta;J. Sugama;C. Konya;J. Matsuo;M. Matsumoto;K. Yabunaka;T. Nakatani;K. Tabata
OBJECTIVE
To reveal the specific ultrasonic imaging findings of non-visible necrotic tissue in pressure ulcers (PUs) with undermining and describe the images objectively. The predictive validity of the specific images of the undermined necrotic tissue was also determined.
METHOD
Using digital ultrasonography (12 MHz linear transducer, MyLab25; Hitachi Medical Corporation), we imaged PUs with undermining every 2 weeks. PUs were also monitored by DESIGN-R, a PU assessment tool, at the same time.
RESULTS
Ten patients had 11 PUs with undermining and all ulcers were located in the sacral region. The necrotic tissue showed high echogenicity with no layers, unclear borders and an uneven gray level (cloud-like image). Granulation tissue appeared as a low echoic image which had no layers, was of coarse resolution and an even gray level. There were significant differences between the pixel uniformity of the necrotic tissue (84.0) and granulation tissue (53.9) compared with uninjured tissue (65.5; p=0.000 and 0.005, respectively). The sensitivity, specificity, and positive and negative predictive values of cloud-like image were 87.5%, 91.7%, 77.8% and 95.6%, respectively.
CONCLUSION
The results suggest that cloud-like image is the most useful diagnostic indicator for non-visible necrotic tissue in PUs with undermining and is the best prognostic indicator for PU healing.
DECLARATION OF INTEREST
The authors have no conflicts of interest to declare. There were no external sources of funding for this study.