Effect of applied load and grit size on wear coefficients of Al 6082–SiC–Gr hybrid composites under two body abrasion

Effect of applied load and grit size on wear coefficients of Al 6082–SiC–Gr hybrid composites under two body abrasion
复制标题

DOI:
10.1016/j.triboint.2016.07.018
复制
发表时间:
2016-11
影响因子:
6.2
通讯作者:
N. Kaushik;R. Rao
N. Kaushik;R. Rao
中科院分区:
工程技术1区
文献类型:
--
作者:
N. Kaushik;R. Rao

文献摘要

被引文献

相似文献

在销盘磨损试验机上,在载荷5-15 N、磨粒尺寸100-200 μm、滑动距离75 m条件下,研究了载荷和磨粒尺寸对Al 6082-5%SiC-5%Gr混杂复合材料两体磨料磨损系数的影响。在较低载荷和较大粒度下,铸造条件下,合金和混杂复合材料的磨损系数分别从0.771× 10 − 3降低到0.547×10− 3和0.73×10− 3降低到0.642×10− 3。但在较高载荷和磨粒尺寸下,磨损系数略有下降,铸态从0.48×10− 3降至0.46×10− 3,T6态从0.497×10− 3降至0.42×10− 3。磨损系数随载荷的增大而减小,随磨粒尺寸的增大而增大。对磨损表面进行了研究,以了解磨损机理。
The effect of applied load and grit size on two body abrasive wear coefficients of Al 6082–5%SiC–5%Gr hybrid composites was evaluated under pin on disc equipment at 5–15 N load, 100–200 µm grit size and 75 m sliding distance. At lower load and higher grit size, the wear coefficient decreases from 0.771×10−3to 0.547×10−3in cast condition; 0.73×10−3to 0.642×10−3in T6 condition when compared alloy to hybrid composite respectively. But at higher load and grit size, the wear coefficient marginally decreased from 0.48×10−3to 0.46×10−3in cast condition; 0.497×10−3to 0.42×10−3in T6 condition respectively. The wear coefficients decreased and increased with increase in load and grit size respectively. The investigation on worn surfaces was done to understand wear mechanism.