REPRODUCIBILITY OF RESTING CEREBRAL BLOOD-FLOW MEASUREMENTS WITH H215O POSITRON EMISSION TOMOGRAPHY IN HUMANS
REPRODUCIBILITY OF RESTING CEREBRAL BLOOD-FLOW MEASUREMENTS WITH H215O POSITRON EMISSION TOMOGRAPHY IN HUMANS
复制标题
DOI:
10.1038/jcbfm.1993.95
复制
发表时间:
1993-09-01
影响因子:
6.3
通讯作者:
PAUL, SM
中科院分区:
文献类型:
--
作者:
MATTHEW, E;ANDREASON, P;PAUL, SM
Two consecutive measurements of resting CBF were carried out in normal volunteers (n = 25) using (H2O)-O-15 positron emission tomography. Absolute whole-brain blood flow (WBBF; ml 100 g-1 min-1, mean +/- SD) for the first (40.3 +/- 6.4) and second (39.3 +/- 6.5) measurements was not significantly different (mean % difference 2.3 +/- 8.7). Analysis of regions of interest showed no significant differences in absolute regional CBF (rCBF) and normalized (rCBF/WBBF) rCBF. Left-right differences were also not significant. These data demonstrate the reproducibility of resting CBF measurements in normal humans.