MR Spectroscopy to Distinguish between Supratentorial Intraventricular Subependymoma and Central Neurocytoma

MR Spectroscopy to Distinguish between Supratentorial Intraventricular Subependymoma and Central Neurocytoma
复制标题

DOI:
10.2463/mrms.mp.2015-0013
复制
发表时间:
2017-01-01
影响因子:
3
通讯作者:
Gabata, Toshifumi
Gabata, Toshifumi
中科院分区:
医学4区
文献类型:
--
作者:
Ueda, Fumiaki;Aburano, Hiroyuki;Gabata, Toshifumi

文献摘要

被引文献

相似文献

目的:目的:应用磁共振波谱(MRS)技术对幕上脑室室管膜下瘤(SIS)和中枢神经细胞瘤(CNC)进行鉴别诊断。他们进行了检查,使用点分辨光谱。测定胆碱(Cho)、N-乙酰天冬氨酸(NAA)、肌醇(MI)和/或甘氨酸(Gly)与肌酸(Cr)的自动计算比值。还进行了Cr对未抑制水(USW)的评价。进行Mann-Whitney U检验以检验代谢物比率差异的显著性。结果:尽管SIS、对照光谱和CNC之间的Cho/Cr有显著性差异(P < 0.0001),但SIS和对照光谱之间的Cho/Cr无显著性差异(P = 0.11)。SIS与CNC(P = 0.04)或对照谱(P < 0.0001)之间的NAA/Cr观察到统计学显著差异。在SIS和对照光谱(P = 0.03)之间以及CNC和对照光谱(P < 0.0006)之间观察到MI和/或Gly与Cr的统计学显著差异。SIS和CNC之间MI和/或Gly与Cr的差异无统计学意义(P = 0.32)。SIS与对照光谱之间(P < 0.0053)、对照光谱与CNC之间(P < 0.0016)、SIS与CNC之间(P < 0.0083)的Cr与USW之间存在显著的统计学差异。在两个SIS中证实了Lac倒置双重峰。结论:MRS可用于鉴别SIS和CNC。
Purpose: The purpose of this study was to discriminate supratentorial intraventricular subependymoma (SIS) from central neurocytoma (CNC) using magnetic resonance spectroscopy (MRS).Methods: Single-voxel proton MRS using a 1.5T or 3T MR scanner from five SISs, five CNCs, and normal controls were evaluated. They were examined using a point-resolved spectroscopy. Automatically calculated ratios comparing choline (Cho), N-acetylaspartate (NAA), myoinositol (MI), and/or glycine (Gly) to creatine (Cr) were determined. Evaluation of Cr to unsuppressed water (USW) was also performed. Mann-Whitney U test was carried out to test the significance of differences in the metabolite ratios. Detectability of lactate (Lac) and alanine (Ala) was evaluated.Results: Although a statistically significant difference (P < 0.0001) was observed in Cho/Cr among SIS, control spectra, and CNC, no statistical difference was noted between SIS and control spectra (P = 0.11). Statistically significant differences were observed in NAA/Cr between SIS and CNC (P = 0.04) or control spectra (P < 0.0001). A statistically significant difference was observed in MI and/or Gly to Cr between SIS and control spectra (P = 0.03), and CNC and control spectra (P < 0.0006). There were no statistical differences between SIS and CNC for MI and/or Gly to Cr (P = 0.32). Significant statistical differences were found between SIS and control spectra (P < 0.0053), control spectra and CNC (P < 0.0016), and SIS and CNC (P < 0.0083) for Cr to USW. Lac inverted doublets were confirmed in two SISs. Triplets of Lac and Ala were detected in four spectra of CNC.Conclusion: The present study showed that MRS can be useful in discriminating SIS from CNC.