Research on air-source heat pump coupled with economized vapor injection scroll compressor and ejector

Research on air-source heat pump coupled with economized vapor injection scroll compressor and ejector
复制标题

DOI:
10.1016/j.ijrefrig.2010.06.003
复制
发表时间:
2011-11
期刊:
International Journal of Refrigeration-revue Internationale Du Froid
影响因子:
--
通讯作者:
Xu Shuxue;Ma Guoyuan
Xu Shuxue;Ma Guoyuan
中科院分区:
其他
文献类型:
--
作者:
Xu Shuxue;Ma Guoyuan

文献摘要

被引文献

相似文献

The performance of the heat pump can be improved further when running under low temperature conditions when an ejector is used in a heat pump system coupled with economized vapor injection (EVI) scroll compressor. In this paper, the design method of the heat pump system with ejector (EVIe) is presented, and the process for designing the heat pump with ejector has been summarized. The optimal location of the vapor injection inlets is at the place where the vapor can inject into the working chambers when they just be closed. The reasonable value for the entrainment ratio u of the ejector is between 0.1 and 0.2. One prototype heat pump was designed under the condition of the evaporation temperature of −20 °C, and an experimental setup was established to test the prototype. The measured results demonstrated that the heating EER of the heat pump system with ejector could reach about 4% higher than that of the system without ejector when the heating capacity remained nearly constant.