An Integrated On-Chip Flux Concentrator for Galvanic Current Sensing

An Integrated On-Chip Flux Concentrator for Galvanic Current Sensing
复制标题

用于电流感测的集成片上磁通集中器

DOI:
--
复制
发表时间:
2018
影响因子:
4.9
通讯作者:
M. M. De Souza
M. M. De Souza
中科院分区:
工程技术2区
文献类型:
--
作者:
Nagaditya Poluri;M. M. De Souza

文献摘要

被引文献

相似文献

提出了一种磁通集中器与电流传感器的片上集成。我们的布局利用了磁通孔中的不连续性,导致磁场穿透到衬底中。通过模拟预测转换因子为96 mT/A,对应于磁增益<inline-formula><tex-math notation="LaTeX">$1.8 与</tex-math></inline-formula>空气相比,所需磁芯的磁导率为500,远低于片外集中器中报道的磁导率,从而显著简化了磁芯材料特性的规格。
On-chip integration of a magnetic flux concentrator with a galvanic current sensor is proposed. Our layout utilizes a discontinuity in a magnetic via, resulting in the penetration of the magnetic field into the substrate. A conversion factor of 96 mT/A is predicted via simulations corresponding to a magnetic gain <inline-formula> <tex-math notation="LaTeX">$1.8 imes $ </tex-math></inline-formula> in comparison with air. The permeability of the magnetic core required is 500, much lower than that reported in off-chip concentrators, resulting in a significant easing of the specifications of the material properties of the core.