Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy.
Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy.
复制标题
DOI:
10.1088/0031-9155/58/7/2349
复制
发表时间:
2013-04-07
影响因子:
3.5
通讯作者:
Munck af Rosenschöld P
中科院分区:
文献类型:
--
作者:
Pommer T;Falk M;Poulsen PR;Keall PJ;O'Brien RT;Petersen PM;Munck af Rosenschöld P
This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 seconds. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7–100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7–99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with > 3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf position constraint had minimal dosimetric effect, DMLC tracking improved the target and normal tissue dose distributions compared to no tracking for target motion >3 mm, with the DMLC tracking distributions showing generally good agreement between the planned and delivered doses.
登录
查看更多内容
影响因子:
5.7
作者:
De Meerleer, G;Villeirs, G;De Neve, W
通讯作者:
De Neve, W
影响因子:
5.7
作者:
Falk, Marianne;af Rosenschold, Per Munck;Korreman, Stine
通讯作者:
Korreman, Stine
影响因子:
2.1
作者:
Puech, Philippe;Potiron, Eric;Villers, Arnauld
通讯作者:
Villers, Arnauld
DOI:
10.1016/s0360-3016(02)02795-5
发表时间:
2002-07-01
影响因子:
7
作者:
Cellini, N;Morganti, AG;Smaniotto, D
通讯作者:
Smaniotto, D
影响因子:
5.7
作者:
Depuydt, Tom;Verellen, Dirk;De Ridder, Mark
通讯作者:
De Ridder, Mark