Measurements of Ohmic Losses of Metallic Reflectors at 140 GHz Using a 3-Mirror Resonator Technique
Measurements of Ohmic Losses of Metallic Reflectors at 140 GHz Using a 3-Mirror Resonator Technique
复制标题
使用 3 镜谐振器技术测量 140 GHz 金属反射器的欧姆损耗
DOI:
10.1023/a:1015064616703
复制
发表时间:
2001
期刊:
影响因子:
--
通讯作者:
R. Wacker
中科院分区:
文献类型:
--
作者:
W. Kasparek;A. Fernández;F. Hollmann;R. Wacker
The reflectivity of metallic mirrors in the millimeter wave region does not only depend on the material, but also on the structure and roughness of the surface. We have performed measurements of the reflectivity of various plane and grooved metallic and graphite samples at 140 GHz. The technique is based on the comparison of the quality factor of a 2-mirror reference resonator with the quality factor of a 3-mirror resonator which has identical dimensions and includes the mirror to be tested. After a brief presentation of the theory, the set-up is described and the reflection loss for various aluminium and copper mirrors as well as vacuum compatible materials for applications in thermonuclear fusion experiments are presented and discussed.