Enhanced microfiltration devices configured with hydrodynamic trapping and a rain drop bypass filtering architecture for microbial cells detection

Enhanced microfiltration devices configured with hydrodynamic trapping and a rain drop bypass filtering architecture for microbial cells detection
复制标题

DOI:
10.1039/b800015h
复制
发表时间:
2008-01-01
期刊:
影响因子:
6.1
通讯作者:
Liu, Wen-Tso
Liu, Wen-Tso
中科院分区:
工程技术1区
文献类型:
--
作者:
Lay, Christophe;Teo, Cheng Yong;Liu, Wen-Tso

文献摘要

被引文献

相似文献

需要超细(< 1 μ m)微过滤器来有效地捕获微生物细胞。我们设计了具有雨滴旁路结构的微滤波器,以有限的电池损失为代价,显着降低了堵塞的可能性。与我们上一代的微滤设备相比,新的雨滴旁路结构配置具有显着降低的压降,并且可以更好地捕获原生动物细胞(小隐孢子虫和贾第鞭毛虫)。一种显示亚微米过滤器间隙的改进版本被用于捕获和检测细菌细胞(大肠杆菌),通过细胞标记方法,旨在放大荧光信号发射,从而提高检测灵敏度。
Ultra-fine (< 1 mu m) microfilters are required to effectively trap microbial cells. We designed microfilters featuring a rain drop bypass architecture, which significantly reduces the likelihood of clogging at the cost of limited cell loss. The new rain drop bypass architecture configuration has a substantially lower pressure drop and allows a better efficiency in trapping protozoan cells ( Cryptosporidium parvum and Giardia lamblia) in comparison to our previous generation of a microfilter device. A modified version displaying sub-micron filter gaps was adapted to trap and detect bacterial cells ( Escherichia coli), through a method of cells labeling, which aims to amplify the fluorescence signal emission and therefore the sensitivity of detection.