Narrow-band tunable wavelength-selective filters of Fabry-Perot interferometers with a liquid crystal intracavity
Narrow-band tunable wavelength-selective filters of Fabry-Perot interferometers with a liquid crystal intracavity
复制标题
内腔液晶法布里-珀罗干涉仪窄带可调谐波长选择滤光片
DOI:
--
复制
发表时间:
1991
影响因子:
2.6
通讯作者:
T. Kurokawa
中科院分区:
文献类型:
--
作者:
K. Hirabayashi;H. Tsuda;T. Kurokawa
Optimum designs for tunable wavelength-selective filters of Fabry-Perot interferometers with a liquid crystal intracavity are described. A nematic liquid crystal with index numbers 1.5506 and 1.4771 was used. Methods of aligning liquid crystal molecules were studied. The filters provide high finesse (150-410), high transmittance (20-70%), narrow transmission peak (FWHM: 0.17-0.35 nm), and a large shift (>50 nm) at a wavelength of 1.5 mu m. These filters have a potential to select over 50 channels in WDM.<<ETX>>