Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
Time-domain reconstruction for thermoacoustic tomography in a spherical geometry
复制标题
DOI:
10.1109/tmi.2002.801176
复制
发表时间:
2002-07-01
影响因子:
10.6
通讯作者:
Wang, LHV
中科院分区:
文献类型:
--
作者:
Xu, MH;Wang, LHV
Reconstruction-based microwave-induced thermoacoustic tomography in a spherical configuration is presented. Thermoacoustic waves from biological tissue samples excited by microwave pulses are measured by a wide-band unfocused ultrasonic transducer, which is set on a spherical surface enclosing the sample. Sufficient data are acquired from different directions to reconstruct the microwave absorption distribution. An exact reconstruction solution is derived and approximated to a modified backprojection algorithm. Experiments demonstrate that the reconstructed images agree well with the original samples. The spatial resolution of the system reaches 0.5 mm.