Shock tube study on ignition delay of multi-component syngas mixtures – Effect of equivalence ratio
Shock tube study on ignition delay of multi-component syngas mixtures – Effect of equivalence ratio
复制标题
DOI:
10.1016/j.ijhydene.2014.01.170
复制
发表时间:
2014-04
影响因子:
7.2
通讯作者:
L. Thi;Yingjia Zhang;Zuo-hua Huang
中科院分区:
文献类型:
--
作者:
L. Thi;Yingjia Zhang;Zuo-hua Huang
Ignition delays were measured in a shock tube for syngas mixtures with argon as diluent at equivalence ratios of 0.3, 1.0 and 1.5, pressures of 0.2, 1.0 and 2.0 MPa and temperatures from 870 to 1350 K. Results show that the influences of equivalence ratio on the ignition of syngas mixtures exhibit different tendency at different temperatures and pressures. At low pressure, the ignition delay increases with an increase in equivalence ratio at tested temperature. At high pressures, however, an opposite behavior is presented, that is, increasing equivalence ratio inhibits the ignition at high temperature and vice versa at intermediate temperature. The affecting degree of equivalence ratio on ignition delay is different for each mixture at given condition, especially for the syngas with high CO concentration. Sensitivity analyses demonstrate that reaction H + O2= O + OH (R1) dominates the syngas oxidation under all conditions. With the increase of CO mole fraction, reactions CO + OH = CO2+ H (R27) and CO + HO2= CO2+ OH (R29) become more important in the syngas ignition kinetics. With the increase of pressure, the reactions related to HO2and H2O2play the dominate role. The opposite influence of equivalence ratio on ignition delay at high- and intermediate-temperatures is chemically interpreted through kinetic analyses.