Infrared Imaging for Leak Detection of N95 Filtering Facepiece Respirators: A Pilot Study
Infrared Imaging for Leak Detection of N95 Filtering Facepiece Respirators: A Pilot Study
复制标题
DOI:
10.1002/ajim.20970
复制
发表时间:
2011-08-01
影响因子:
3.5
通讯作者:
Bergman, Michael S.
中科院分区:
文献类型:
--
作者:
Roberge, Raymond J.;Monaghan, William D.;Bergman, Michael S.
Background This study was undertaken to determine the utility of an infrared camera (IRC) for assessing leaks around filtering facepiece respirators (FFR) during quantitative respirator fit testing.Methods Eight subjects underwent quantitative fit testing on six N95 FFR models (48 total fit tests) while simultaneously being recorded with an IRC.Results The IRC detected 49 exhalation leaks during 39 tests and no leaks in nine tests. Exhalation leaks were identified in all failed fit tests (13) and a majority (26 of 35) of passed tests. Anatomically, the nasal region and malar (cheekbone) regions accounted for 71% of identified leak sites. Fit factors for fit tests without identified exhalation leaks were significantly higher than fit tests with leaks detected by IRC (P = 0.01).Conclusions Thermal imaging using IRC can detect leaks in respiratory protective equipment and has the potential as a screening tool for assessment of the adequacy of post-donning FFR fit. Am. J. Ind. Med. 54:628-636, 2011. (C) 2011 Wiley-Liss, Inc.