Intra- and inter-observer reproducibility of volume measurement of knee cartilage segmented from the OAI MR image set using a novel semi-automated segmentation method
Intra- and inter-observer reproducibility of volume measurement of knee cartilage segmented from the OAI MR image set using a novel semi-automated segmentation method
复制标题
DOI:
10.1016/j.joca.2009.06.003
复制
发表时间:
2009-12-01
影响因子:
7
通讯作者:
Kwoh, C. K.
中科院分区:
文献类型:
--
作者:
Bae, K. T.;Shim, H.;Kwoh, C. K.
Objective: We developed a semi-automated method based on a graph-cuts algorithm for segmentation and volumetric measurements of the cartilage from high-resolution knee magnetic resonance (MR) images from the Osteoarthritis Initiative (OAI) database and assessed the intra- and inter-observer reproducibility of measurements obtained via this method.Design: MR image sets from 20 subjects of varying Kellgren-Lawrence (KL) grades (from 0 to IV) on fixed flexion knee radiographs were selected from the baseline double-echo and steady-state (DESS) knee MR images in the OAI database (0.B.1 Imaging Data set). Two trained radiologists independently performed the segmentation of knee cartilage twice using the semi-automated method. The volumes of segmented cartilage were computed and compared. The intra- and inter-observer reproducibility were determined by means of the coefficient of variation (CV%) of repeated cartilage segmented volume measurements. The subjects were also divided into the low- (0, I or II) and high-KL (III or IV) groups. The differences in cartilage volume measurements and CV% within and between the observers were tested with t tests.Results: The mean (+/- SD) intra-observer CV% for the 20 cases was 1.29 (+/- 1.05)% for observer 1 and 1.67 (+/- 1.14)% for observer 2, while the mean (+/- SD) inter-observer CV% was 1.31 (+/- 1.26)% for session 1 and 1.79 (+/- 1.72)% for session 2. There was no significant difference between the two intra-observer CV%'s (P = 0.272) and between the two inter-observer CV%'s (P = 0.353). The mean intra-observer CV% of the low-KL group was significantly smaller than that for the high-KL group for observer 1 (0.83 vs 1.86%: P = 0.025). The segmentation processing times used by the two observers were significantly different (observer 1 vs 2): (mean 49 +/- 12 vs 33 +/- 6 min) for session 1 and (49 +/- 8 vs 32 +/- 8 min) for session 2.Conclusion: The semi-automated graph-cuts method allowed us to segment and measure cartilage from high-resolution 3 T MR images of the knee with high intra- and inter-observer reproducibility in subjects with varying severity of CA. (C) 2009 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.