The Parallel Resonant Converters (PRC) are commonly equipped with a high frequency transformer (HFT), in order to provide an isolation and to adjust the current/voltage values. This study, investigates the effects of HFT on the operation of PRC, by utilizing Bode Diagrams. Simulation results are presented.