Dose distribution in the Russian Segment of the International Space Station.
Dose distribution in the Russian Segment of the International Space Station.
复制标题
国际空间站俄罗斯部分的剂量分布。
DOI:
10.1093/rpd/nci566
复制
发表时间:
2006
影响因子:
1
通讯作者:
V. Arkhangelsky
中科院分区:
文献类型:
--
作者:
M. Hajek;T. Berger;M. Fugger;M. Fürstner;N. Vana;Y. Akatov;V. Shurshakov;V. Arkhangelsky
Absorbed dose and average linear energy transfer (LET) were assessed by means of (7)LiF:Mg,Ti (TLD-700) thermoluminescent (TL) detectors for different panels on-board the Russian Segment of the International Space Station in the timeframe between March and November 2002 (233 d). A technique is presented to correct the measured absorbed dose values for TL efficiency in the radiation climate on-board the spacecraft. Average LET is determined from the high-temperature TL emission in the TLD-700 glow curve and used as a parameter in the TL efficiency correction. Depending on the shielding distribution, the efficiency-corrected absorbed dose varies between 154 +/- 5 microGy d(-1) in panel no. 327 (core block ceiling) and 191 +/- 3 microGy d(-1) in panel no. 110 (core block central axis, floor). The experimental data are compared with the model calculations by using detailed shielding distributions and orbit parameters as inputs.