Evaluation of the optimal turbine pressure drop ratio for a solar chimney power plant
Evaluation of the optimal turbine pressure drop ratio for a solar chimney power plant
复制标题
太阳能烟囱发电厂最佳涡轮机压降比的评估
DOI:
10.1016/j.enconman.2015.10.076
复制
发表时间:
2016
影响因子:
10.4
通讯作者:
Wang Yuan
中科院分区:
文献类型:
--
作者:
Guo Penghua;Li Jingyin;Wang Yunfeng;Wang Yuan
The optimal turbine pressure drop ratiofoptfor a solar chimney power plant (SCPP) is investigated using an analytical approach and 3D numerical simulations. Results indicate that the solar radiation and ambient temperature have obvious influences to the optimal turbine pressure drop ratiofoptand an improved performance of the SCPP system leads to a highfopt. The performance comparison between the cases with different collector shapes, a circular collector and a square collector with the same area, is conducted for the first time. It is found that them-th power law assumption can also be applied to the SCPP system with a square collector; the values offoptfor the cases with a square collector are close to those for the cases with a circular collector. A fitting equation with variables of solar radiation and ambient temperature is obtained using the simulation results of the Spanish prototype; the results reveal that thefoptof the Spanish prototype ranges from 0.90 to 0.94 under normal climate conditions. This paper provides an approach to the preliminary estimation of plant performance, and reference data for an optimal pressure drop through solar chimney turbines.