Fabrication and characteristic study on mixing enhancement of a magnetofluidic mixer

Fabrication and characteristic study on mixing enhancement of a magnetofluidic mixer
复制标题

DOI:
10.1016/j.sna.2021.112733
复制
发表时间:
2021-08
期刊:
Sensors and Actuators A: Physical
影响因子:
--
通讯作者:
Ran Zhou;A. Surendran;Jingya Wang
Ran Zhou;A. Surendran;Jingya Wang
中科院分区:
其他
文献类型:
--
作者:
Ran Zhou;A. Surendran;Jingya Wang

文献摘要

相似文献

The needs for fast mixing of two miscible fluids in microfluidic device is increasing recently and has been widely used for DNA synthesis, clinic diagnostics and chemical reaction. However, the mixing at microscale relies heavily on slow molecular diffusion because of its low Reynolds number and thus laminar flow. In this work, therefore, a magnetofluidic mixer with the integration of magnetic field is presented for rapid mixing between ferrofluid and distilled water with no harmful Joule heat generated. Parametric study of experiment and simulation was performed to discuss the effect of flow rate, placement angle of magnet and width of magnet on the mixing efficiency between two fluids. It was found that the mixing performance of 0.76 was the most homogeneous when the angle α= 1/12π because of the acceleration-deceleration couples (ADC) and mass conservation law. It was also found that the mixing performance increases from 0.13 to 0.49 as the magnet width increases from w m= 50 μ m to w m= 250 μ m while decreases when magnet width is wider than w m= 250 μ m due to local reduced Peclet number. The developed micromixer and mixing mechanism will be of great potentials and insight for future quick optimization of biomedical and chemical mixing devices.