Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method

Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method
复制标题

DOI:
10.1590/s0100-40422013000700020
复制
发表时间:
2013-01-01
期刊:
Química Nova
影响因子:
--
通讯作者:
Kara, Huseyin
Kara, Huseyin
中科院分区:
其他
文献类型:
--
作者:
Kucukkolbasi, Semahat;Bilber, Onur;Kara, Huseyin

文献摘要

被引文献

相似文献

在本研究中,反相高效液相色谱法(RP-HPLC)的程序开发和验证的同时测定7个水溶性维生素(硫胺素,核黄素,烟酸,氰钴胺,抗坏血酸,叶酸,和对氨基苯甲酸)和4个脂溶性维生素(视黄醇醋酸酯,胆钙化醇,α-生育酚,和植物甲萘醌)的复合维生素片。在10-500 ng/mL范围内,线性关系良好(R-2 > 0.999)。通过进行日内和日间精密度,对该方法进行统计学评价。通过测量平均回收率检测方法的准确度;值范围为87.4%-98.5%,是符合标示量的可接受定量结果。
In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC) procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid) and four fat-soluble vitamins (retinol acetate, cholecalciferol, alpha-tocopherol, and phytonadione) in multivitamin tablets. The linearity of the method was excellent (R-2 > 0.999) over the concentration range of 10-500 ng mL(-1). The statistical evaluation of the method was carried out by performing the intra-and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.