Liquid radwaste concentration by evaporation from porous plates
Liquid radwaste concentration by evaporation from porous plates
复制标题
DOI:
10.1007/s10512-009-9162-x
复制
发表时间:
2009-07
期刊:
影响因子:
0.5
通讯作者:
S. Dmitriev;Y. V. Karlin;M. A. Maryakhin;Y. G. Myasnikov;Yu. T. Slastennikov
中科院分区:
文献类型:
--
作者:
S. Dmitriev;Y. V. Karlin;M. A. Maryakhin;Y. G. Myasnikov;Yu. T. Slastennikov
The possibility of concentrating liquid radwastes by evaporation from the surface of porous plates is examined. It is shown by means of tests of a laboratory setup and an experimental stand that liquid radwastes can be concentrated to salt content 319 g/liter at a temperature far below the evaporation temperature of water and with specific energy consumption 20 times lower that the specific heat of vaporization of water. The results of the tests of the experimental setup with capacity up to 43 kg/h with respect to the evaporated water are described; this setup has been incorporated in the EKO mobile modular water purification complex used at the MosNPO Radon for reprocessing radioactive water from various organizations.