我们旨在研究血液净化和冷盐水注射部位对经皮热稀释值的影响。我们测量了8只猪在冷盐水注射(左颈静脉和股静脉)和血液净化部位(右颈静脉和股静脉)的每种组合中的心输出量,有或没有血液净化。我们检查了存在和不存在血液净化、血液净化的血管部位和冷盐水注射部位之间的差异对经肺热稀释值的影响。使用经皮热稀释法进行血液净化期间测得的心输出量被低估;然而,血管部位之间无差异。通过股静脉注射冷盐水测得的心输出量高于通过颈静脉注射冷盐水测得的心输出量,无论是否进行血液净化。
We aimed to investigate the effects of blood purification and cold saline injection sites on the transpulmonary thermodilution values. We measured the cardiac output of eight pigs in every combination of cold saline injection (left jugular and femoral veins) and blood purification sites (right jugular and femoral veins), with or without blood purification. We examined the influence of the difference between the presence and absence of blood purification, vascular sites for blood purification, and sites for cold saline injection on the transpulmonary thermodilution values. Cardiac output measured during blood purification using transpulmonary thermodilution was underestimated; however, there was no difference between vascular sites. Cardiac output measured via injection of cold saline into the femoral vein was higher than that obtained through injection of cold saline into the jugular vein, with or without blood purification.
DOI: 10.1186/s13054-017-1739-5
发表时间: 2017-06-19
期刊: Critical care (London, England)
影响因子: --
作者:
Monnet X;Teboul JL
通讯作者: Teboul JL
DOI: 10.1111/1744-9987.12193
发表时间: 2015
影响因子: 1.9
作者:
F. Compton;M. Vogel;W. Zidek;M. Giet;T. Westhoff
通讯作者: T. Westhoff
使用 EV1000 系统进行连续静脉-静脉血液滤过对经肺热稀释测量的功效。
DOI: --
发表时间: 2015
影响因子: 1.5
作者:
K. Nakamura;R. Inokuchi;T. Hiruma;K. Doi
通讯作者: K. Doi
连续肾脏替代疗法对使用热稀释技术测量心输出量的影响。
DOI: --
发表时间: 2012
影响因子: 3.2
作者:
D. Heise;M. Faulstich;O. Mörer;A. Bräuer;M. Quintel
通讯作者: M. Quintel
DOI: 10.1213/01.ane.0000280440.08530.fb
发表时间: 2007-10-01
影响因子: 5.7
作者:
Sakka, Samir G.;Hanusch, Tino;Wegscheider, Karl
通讯作者: Wegscheider, Karl