A safe optically guided entry technique using Endopath Xcel Trocars in laparoscopic surgery: A personal series of 821 patients
A safe optically guided entry technique using Endopath Xcel Trocars in laparoscopic surgery: A personal series of 821 patients
复制标题
在腹腔镜手术中使用 Endopath Xcel Trocars 的安全光学引导进入技术:821 名患者的个人系列
DOI:
10.1016/j.gmit.2012.12.006
复制
发表时间:
2013
期刊:
影响因子:
--
通讯作者:
W. Wong
中科院分区:
文献类型:
--
作者:
W. Wong
ObjectiveTo demonstrate the technique and clinical safety of primary entry of an optically guided entry approach in laparoscopic surgery.MaterialsThe clinical data from a personal series of 821 consecutive cases of laparoscopic surgery were used.MethodsThe technique of an optically guided primary entry using an Endopath Xcel trocar was described.ResultsThere was no bowel, vascular, or visceral complication in this series. This entry approach was also safe in those with high surgical risks, for example, high body mass index, multiple previous abdominal surgeries and previous laparotomy. There was no failed entry, no extraperitoneal insufflation, no wound infection and wound hernia.ConclusionIn this personal series, the findings demonstrated the safety and feasibility of an optically guided entry technique in laparoscopic surgeries.