Investigation of the output droop characteristics of parallel-connnected DC-DC converters
Investigation of the output droop characteristics of parallel-connnected DC-DC converters
复制标题
并联 DC-DC 转换器的输出下降特性研究
DOI:
10.1109/pesc.1994.373859
复制
发表时间:
1994
期刊:
影响因子:
--
通讯作者:
H. Lee
中科院分区:
文献类型:
--
作者:
I. Batarseh;K. Siri;H. Lee
The analytical proof that output voltage droop characteristics of parallel-connected DC-DC power converters are only appropriate for very limited applications is presented. Because the converters are rarely made to be identical, near-uniform current-sharing without additional control can be achieved only when converters connected in parallel have similar characteristics of being very close to the ideal current sources. This can occur at a cost of poor voltage regulation. As an alternative, the current-sharing control technique, which requires no remote-sensing, is proposed. The technique ensures uniform or designated current distribution throughout the specified load range. A control circuit module is independently implemented without any preliminary knowledge or any circuit modification of the source converters.<<ETX>>