Radio frequency dual-spectra analysis of regional myocardial perfusion: Comparison with harmonic densitometric method.

Radio frequency dual-spectra analysis of regional myocardial perfusion: Comparison with harmonic densitometric method.
复制标题

局部心肌灌注的射频双谱分析:与谐波密度法的比较。

DOI:
10.1067/mje.2002.122967
复制
发表时间:
2002
期刊:
Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
影响因子:
--
通讯作者:
M. Belohlavek
M. Belohlavek
中科院分区:
--
文献类型:
--
作者:
T. Asanuma;B. Khandheria;J. Seward;M. Belohlavek

文献摘要

参考文献

被引文献

相似文献

我们的目的是比较谐波-基频比峰值(HFRP)分析与传统的谐波灰度密度分析的基础上,消除超声信号的异质性的能力。在10只开胸猪中,在注入造影剂微泡之前和期间,通过使用间歇短轴扫描获得宽带射频和谐波数据。测量左室心肌6个节段的HFRP和灰阶强度值。在基线图像中,各向异性对HFRP值的影响显著小于灰度强度。在减影灌注评估中,HFRP值的对比度异质性显著小于灰度强度。减影后HFRP值的增加显著大于侧(P <0.001)、后(P <0.0001)和下(P <0.01)心肌的灰度强度。HFRP分析可以补偿基线心肌各向异性和局部对比度异质性。通过背景减除,HFRP分析可以更好地量化心肌灌注。
Our objective was to compare harmonic-to-fundamental frequency ratio peak (HFRp) analysis with conventional harmonic gray-scale densitometric analysis on the basis of ability to eliminate heterogeneity in ultrasound signals. Broadband radio frequency and harmonic data were obtained by using intermittent short-axis scans in 10 open-chest pigs before and during infusion of contrast microbubbles. HFRp and gray-scale intensity values were measured in 6 segments of left ventricular myocardium. In baseline images, the influence of anisotropy on HFRp values was significantly less than that in gray-scale intensities. In perfusion assessment with subtraction, contrast heterogeneity in HFRp values was significantly smaller than that in gray-scale intensities. The increase in HFRp values after subtraction was significantly greater than that in gray-scale intensities in lateral (P <.001), posterior (P <.0001), and inferior (P <.01) myocardium. HFRp analysis can compensate for baseline myocardial anisotropy and regional contrast heterogeneity. With background subtraction, HFRp analysis allows better quantification of myocardial perfusion.
心肌造影超声心动图检测冠状动脉疾病:与 99mTc-sestamibi 单光子发射计算机断层扫描的比较。
DOI: --
发表时间: 1997
期刊: Circulation
影响因子: 37.8
作者:
Kaul,S;Senior,R;Dittrich,H;Raval,U;Khattar,R;Lahiri,A
通讯作者: Lahiri,A
冠状动脉和心肌血量:评估冠状动脉微循环的无创工具?
DOI: --
发表时间: 1997
期刊: Circulation
影响因子: 37.8
作者:
Kaul,S;Jayaweera,AR
通讯作者: Jayaweera,AR
DOI: 10.4065/73.11.1066
发表时间: 1998
影响因子: 8.9
作者:
Belohlavek,M;Tanabe,K;Mulvagh,SL;Foley,DA;Greenleaf,JF;Seward,JB
通讯作者: Seward,JB
DOI: 10.1161/01.cir.97.5.473
发表时间: 1998-02
期刊: Circulation
影响因子: 37.8
作者:
K. Wei;A. Jayaweera;S. Firoozan;A. Linka;D. Skyba;S. Kaul
通讯作者: K. Wei;A. Jayaweera;S. Firoozan;A. Linka;D. Skyba;S. Kaul
DOI: 10.1016/s0002-8703(00)90231-x
发表时间: 2000-02-01
影响因子: 4.8
作者:
Lindner, JR;Villanueva, FS;Kaul, S
通讯作者: Kaul, S