Clinical implementation of intrafraction cone beam computed tomography imaging during lung tumor stereotactic ablative radiation therapy.

Clinical implementation of intrafraction cone beam computed tomography imaging during lung tumor stereotactic ablative radiation therapy.
复制标题

DOI:
10.1016/j.ijrobp.2013.08.015
复制
发表时间:
2013-12-01
影响因子:
7
通讯作者:
Loo, Billy W., Jr.
Loo, Billy W., Jr.
中科院分区:
医学1区
文献类型:
--
作者:
Li, Ruijiang;Han, Bin;Meng, Bowen;Maxim, Peter G.;Xing, Lei;Koong, Albert C.;Diehn, Maximilian;Loo, Billy W., Jr.

文献摘要

参考文献

被引文献

相似文献

To develop and clinically evaluate a volumetric imaging technique for assessing intrafraction geometric and dosimetric accuracy of stereotactic ablative radiation therapy (SABR). Twenty patients received SABR for lung tumors using volumetric modulated arc therapy (VMAT). At the beginning of each fraction, pretreatment cone beam computed tomography (CBCT) was used to align the soft-tissue tumor position with that in the planning CT. Concurrent with dose delivery, we acquired fluoroscopic radiograph projections during VMAT using the Varian on-board imaging system. Those kilovolt projections acquired during megavolt beam-on were automatically extracted, and intrafraction CBCT images were reconstructed using the filtered backprojection technique. We determined the time-averaged target shift during VMAT by calculating the center of mass of the tumor target in the intrafraction CBCT relative to the planning CT. To estimate the dosimetric impact of the target shift during treatment, we recalculated the dose to the GTV after shifting the entire patient anatomy according to the time-averaged target shift determined earlier. The mean target shift from intrafraction CBCT to planning CT was 1.6, 1.0, and 1.5 mm; the 95th percentile shift was 5.2, 3.1, 3.6 mm; and the maximum shift was 5.7, 3.6, and 4.9 mm along the anterior-posterior, left-right, and superior-inferior directions. Thus, the time-averaged intrafraction gross tumor volume (GTV) position was always within the planning target volume. We observed some degree of target blurring in the intrafraction CBCT, indicating imperfect breath-hold reproducibility or residual motion of the GTV during treatment. By our estimated dose recalculation, the GTV was consistently covered by the prescription dose (PD), that is, V100% above 0.97 for all patients, and minimum dose to GTV >100% PD for 18 patients and >95% PD for all patients. Intrafraction CBCT during VMAT can provide geometric and dosimetric verification of SABR valuable for quality assurance and potentially for treatment adaptation.
DOI: 10.1118/1.3582693
发表时间: 2011-05-01
期刊: MEDICAL PHYSICS
影响因子: 3.8
作者:
Li, Ruijiang;Lewis, John H.;Jiang, Steve B.
通讯作者: Jiang, Steve B.
DOI: 10.1016/j.ijrobp.2012.03.006
发表时间: 2012-08-01
影响因子: 7
作者:
Li, Ruijiang;Mok, Edward;Xing, Lei
通讯作者: Xing, Lei
DOI: 10.1016/j.ijrobp.2009.08.005
发表时间: 2010-04-01
影响因子: 7
作者:
Tai, An;Christensen, James D.;Li, X. Allen
通讯作者: Li, X. Allen
DOI: 10.1016/j.radonc.2011.08.019
发表时间: 2011-09-01
影响因子: 5.7
作者:
van Herk, Marcel;Ploeger, Lennert;Sonke, Jan-Jakob
通讯作者: Sonke, Jan-Jakob
DOI: 10.1016/j.ijrobp.2008.11.066
发表时间: 2009-11-01
影响因子: 7
作者:
Bissonnette, Jean-Pierre;Franks, Kevin N.;Bezjak, Andrea
通讯作者: Bezjak, Andrea