Beam Current Monitor with a High-Tc Current Sensor and SQUID at the RIBF
Beam Current Monitor with a High-Tc Current Sensor and SQUID at the RIBF
复制标题
RIBF 处配有高温电流传感器和 SQUID 的束流监控器
DOI:
10.1007/s10948-012-1943-0
复制
发表时间:
2012
影响因子:
1.8
通讯作者:
K. Kon
中科院分区:
文献类型:
--
作者:
T. Watanabe;N. Fukunishi;M. Kase;O. Kamigaito;S. Inamori;K. Kon
It is widely recognized that non-destructive measurement at high resolution of the DC current of high-energy heavy-ion beams is important. Therefore, a high critical temperature (HTc) superconducting quantum interference device (SQUID) beam current monitor has been developed for use in the radioactive isotope beam factory (RIBF) at RIKEN in Japan. Unlike at other existing facilities, a low-vibration, pulse-tube refrigerator cools the HTc fabrications including the SQUID in such a way that the size of the system is reduced and the running costs are lowered. As a result, using a prototype of the HTc SQUID monitor, the intensity of a 1 μA Xe beam (50 MeV/u) was successfully measured with 100 nA resolution. Furthermore, since a higher resolution is necessary, development of an improved HTc current sensor with two coils has begun. A spraying machine was developed to fabricate the new HTc current sensor by dip-coating a thin layer of Bi2–Sr2–Ca2–Cu3–Ox(Bi-2223) onto a 99.6 % MgO ceramic substrate. Results from a new HTc current sensor produced using this machine are reported here.