High-resolution chemical shift imaging for the assessment of intramuscular lipids

High-resolution chemical shift imaging for the assessment of intramuscular lipids
复制标题

DOI:
10.1002/mrm.21209
复制
发表时间:
2007-05-01
影响因子:
3.3
通讯作者:
den Hollander, Jan A.
den Hollander, Jan A.
中科院分区:
医学3区
文献类型:
--
作者:
Newcomer, Bradley R.;Lawrence, Jeannine C.;den Hollander, Jan A.

文献摘要

被引文献

相似文献

A new high-resolution MRSI technique was used to measure extracellular lipids (EMCL), intracellular lipids (IMCL), and total muscle lipids (TML). The purpose of this study was to assess the feasibility and reproducibility of this new technique. This study also compared results obtained from small regions of interest (ROIs) vs. a summation of a large ROI of voxels representing the total soleus or anterior tibialis (TA) muscles. Eight volunteers were studied with the use of a conventional single slice MR spectroscopic imaging (MRSI) sequence run with the following parameters: TR = 145.9 ms, FOV = 16 cm, slice thickness = 1 cm, and 64 x 64 phase encodes. EMCL, IMCL, and TML values from the small ROIs proved to be reproducible (coefficient of variation (CV) = 7.8-13.8% for soleus, and 8.218% for TA). EMCL, IMCL, and TML values from the larger soleus ROI proved to be reproducible (CV = 7.3-16.1%), whereas the larger TA ROIs were less reproducible. The small and larger soleus ROIs produced statistically equivalent measures of EMCL and TML per unit area. However, the small soleus and TA ROIs showed a trend toward yielding different IMCL contents as compared to the larger ROIs. This study demonstrates that high-resolution H-1 MRSI of the calf muscle is feasible and can reproducibly measure EMCL, IMCL, and TML.